首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This paper presents a new procedure to transform an SSI system into an equivalent SDOF system using twice equivalence. A pushover analysis procedure based on the capacity spectrum method for buildings with SSI effects (PASSI) is then established based on the equivalent SDOF system, and the modified response spectrum and equivalent capacity spectrum are obtained. Furthermore, the approximate formulas to obtain the dynamic stiffness of foundations are suggested. Three steel buildings with different story heights (3, 9 and 20) including SSI effects are analyzed under two far-field and two near-field historical records and an artificial seismic time history using the two PASSI procedures and the nonlinear response history analysis (NLhRHA) method. The results are compared and discussed. Finally, combined with seismic design response spectrum, the nonlinear seismic response of a 9-story building with SSI effects is analyzed using the PASSI procedures, and its seismic performance is evaluated according to the Chinese 'Code for Seismic Design of Buildings. The feasibility of the proposed procedure is verified.  相似文献   

2.
Most current seismic design includes the nonlinear response of a structure through a response reduction factor(R). This allows the designer to use a linear elastic force-based approach while accounting for nonlinear behavior and deformation limits. In fact, the response reduction factor is used in modern seismic codes to scale down the elastic response of a structure. This study focuses on estimating the actual ‘R' value for engineered design/construction of reinforced concrete(RC) buildings in Kathmandu valley. The ductility and overstrength of representative RC buildings in Kathmandu are investigated. Nonlinear pushover analysis was performed on structural models in order to evaluate the seismic performance of buildings. Twelve representative engineered irregular buildings with a variety of characteristics located in the Kathmandu valley were selected and studied. Furthermore, the effects of overstrength on the ductility factor, beam column capacity ratio on the building ductility, and load path on the response reduction factor, are examined. Finally, the results are further analyzed and compared with different structural parameters of the buildings.  相似文献   

3.
The effects of higher modes and torsion have a significant impact on the seismic responses of asymmetric-plan tall buildings.A consecutive modal pushover(CMP) procedure is one of the pushover methods that have been developed to consider these effects.The aim of this paper is to modify the(CMP) analysis procedure to estimate the seismic demands of one-way asymmetric-plan tall buildings with dual systems.An analysis of 10-,15-and 20-story asymmetric-plan buildings is carried out,and the results from the modified consecutive modal pushover(MCMP) procedure are compared with those obtained from the modal pushover analysis(MPA) procedure and the nonlinear time history analysis(NLTHA).The MCMP estimates of the seismic demands of one-way asymmetric-plan buildings demonstrate a reasonable accuracy,compared to the results obtained from the NLTHA.Furthermore,the accuracy of the MCMP procedure in the prediction of plastic hinge rotations is better than the MPA procedure.The new pushover procedure is also more accurate than the FEMA load distribution and the MPA procedure.  相似文献   

4.
Plan asymmetric buildings are very susceptible to earthquake induced damage due to lateral torsional coupling, and the corners of these systems suffer heavy damage during earthquakes. Therefore, it is important to investigate the seismic behavior of an asymmetric plan building with MR dampers. In this study, the effectiveness of MR damper-based control systems has been investigated for seismic hazard mitigation of a plan asymmetric building. Furthermore, the infl uence of the building parameters and damper command voltage on the control performance is examined through parametric study. The building parameters chosen are eccentricity ratio and frequency ratio. The results show that the MR damper-based control systems are effective for plan asymmetric systems.  相似文献   

5.
The pushover analysis (POA) procedure is difficult to apply to high-rise buildings, as it cannot account for the contributions of higher modes. To overcome this limitation, a modal pushover analysis (MPA) procedure was proposed by Chopra et al. (2001). However, invariable lateral force distributions are still adopted in the MPA. In this paper, an improved MPA procedure is presented to estimate the seismic demands of structures, considering the redistribution of inertia forces after the structure yields. This improved procedure is verified with numerical examples of 5-, 9- and 22-story buildings. It is concluded that the improved MPA procedure is more accurate than either the POA procedure or MPA procedure. In addition, the proposed procedure avoids a large computational effort by adopting a two-phase lateral force distribution..  相似文献   

6.
The nonlinear response of structures is usually evaluated by considering two accelerograms acting simultaneously along the orthogonal directions. In this study, the infl uence of the earthquake direction on the seismic response of building structures is examined. Three multi-story RC buildings, representing a very common structural typology in Italy, are used as case studies for the evaluation. They are, respectively, a rectangular plan shape, an L plan shape and a rectangular plan shape with courtyard buildings. Nonlinear static and dynamic analyses are performed by considering different seismic levels, characterized by peak ground acceleration on stiff soil equal to 0.35 g, 0.25 g and 0.15 g. Nonlinear dynamic analyses are carried out by considering twelve different earthquake directions, and rotating the direction of both the orthogonal components by 30° for each analysis(from 0° to 330°). The survey is carried out on the L plan shape structure. The results show that the angle of the seismic input motion signifi cantly infl uences the response of RC structures; the critical seismic angle, i.e., the incidence angle that produces the maximum demand, provides an increase of up to 37% in terms of both roof displacements and plastic hinge rotations.  相似文献   

7.
In this study the seismic pounding response of adjacent multi-degree-of-freedom(MDOF) buildings with bilinear inter-story resistance characteristics is investigated through dimensional analysis. The application of dimensional analysis leads to a condensed presentation of the response, and the remarkable self-similarity property for bilinear MDOF buildings with inelastic collision is uncovered. It is shown that when the response is expressed in the appropriate dimensionless form, response spectra for any intensity of the excitation collapse to a single master curve. The reduced Π set explicitly describes the interaction between the colliding structures. The effect of pounding on the MDOF building's response is illustrated using three well-divided spectral regions(amplifi ed, de-amplifi ed and unaffected regions). Parametric studies are conducted to investigate the effects of the story stiffness of structures, the story stiffness ratio and mass ratio of adjacent buildings, the structural inelastic characteristics and the gap size values. Results show that(i) the infl uence of system stiffness ratio to the lighter and more fl exible building is more signifi cant in the fi rst spectral region, where the maximum response of the building is amplifi ed because of pounding; and(ii) the velocity and pounding force of the heavier and stiffer building is unexpectedly sensitive to the mass ratio of adjacent buildings.  相似文献   

8.
Many urban areas are located in regions of moderate seismicity and are subjected to strong wind. Buildings in these regions are often designed without seismic provisions. As a result, in the event of an earthquake, the potential for damage and loss of lives may not be known. In this paper, the performance of a typical high-rise building with a thick transfer plate (TP), which is one type of building structure commonly found in Hong Kong, is assessed against both earthquake and wind hazards. Seismic- and wind-resistant performance objectives are fi rst reviewed based on relevant codes and design guidelines for high-rise buildings. After a brief introduction of wind-resistant design of the building, various methodologies, including equivalent static load analysis (ESLA), response spectrum analysis (RSA), pushover analysis (POA), linear and nonlinear time-history analysis (LTHA and NTHA), are employed to assess the seismic performance of the building when subjected to frequent earthquakes, design based earthquakes and maximum credible earthquakes. The effects of design wind and seismic action with a common 50-year return period are also compared. The results indicate that most performance objectives can be satisfi ed by the building, but there are some objectives, such as inter-story drift ratio, that cannot be achieved when subjected to the frequent earthquakes. It is concluded that in addition to wind, seismic action may need to be explicitly considered in the design of buildings in regions of moderate seismicity.  相似文献   

9.
It is critical to ensure the functionality of highway bridges after earthquakes to provide access to important facilities. Since the 1971 San Fernando earthquake, there has been a better understanding of the seismic performance of bridges. Nonetheless, there are no detailed guidelines addressing the performance of skewed highway bridges. Several parameters affect the response of skewed highway bridges under both service and seismic loads which makes their behavior complex. Therefore, there is a need for more research to study the effect of skew angle and other related factors on the performance of highway bridges. This paper examines the seismic performance of a three-span continuous concrete box girder bridge with skew angles from 0 to 60 degrees, analytically. Finite element (FE) and simplified beam-stick (BS) models of the bridge were developed using SAP2000. Different types of analysis were considered on both models such as: nonlinear static pushover, and linear and nonlinear time history analyses. A comparison was conducted between FE and BS, different skew angles, abutment support conditions, and time history and pushover analysis. It is shown that the BS model has the capability to capture the coupling due to skew and the significant modes for moderate skew angles. Boundary conditions and pushover load profile are determined to have a major effect on pushover analysis. Pushover analysis may be used to predict the maximum deformation and hinge formation adequately.  相似文献   

10.
Unreinforced Masonry(URM) is the most common partitioning material in framed buildings in India and many other countries.Although it is well-known that under lateral loading the behavior and modes of failure of the frame buildings change significantly due to infill-frame interaction,the general design practice is to treat infills as nonstructural elements and their stiffness,strength and interaction with the frame is often ignored,primarily because of difficulties in simulation and lack of modeling guidelines in design codes.The Indian Standard,like many other national codes,does not provide explicit insight into the anticipated performance and associated vulnerability of infilled frames.This paper presents an analytical study on the seismic performance and fragility analysis of Indian code-designed RC frame buildings with and without URM infills.Infills are modeled as diagonal struts as per ASCE 41 guidelines and various modes of failure are considered.HAZUS methodology along with nonlinear static analysis is used to compare the seismic vulnerability of bare and infilled frames.The comparative study suggests that URM infills result in a significant increase in the seismic vulnerability of RC frames and their effect needs to be properly incorporated in design codes.  相似文献   

11.
For super high-rise buildings,the vibration period of the basic mode is several seconds,and it is very close to the period of the fluctuating wind.The damping of super high-rise buildings is low,so super high-rise buildings are very sensitive to fluctuating wind.The wind load is one of the key loads in the design of super high-rise buildings.It is known that only the basic mode is needed in the wind-response analysis of tall buildings.However,for super high-rise buildings,especially for the acceleration response,because of the frequency amplification of the high modes,the high modes and the mode coupling may need to be considered.Three typical super high-rise projects with the SMPSS in wind tunnel tests and the random vibration theory method were used to analyze the effect of high modes on the wind-induced response.The conclusions can be drawn as follows.First,for the displacement response,the basic mode is dominant,and the high modes can be neglected.Second,for the acceleration response,the high modes and the mode coupling should be considered.Lastly,the strain energy of modes can only give the vibration energy distribution of the high-rise building,and it cannot describe the local wind-induced vibration of high-rise buildings,especially for the top acceleration response.  相似文献   

12.
This study describes the seismic performance of an existing five storey reinforced concrete building which represents the typical properties of low-rise non-ductile buildings in Turkey. The effectiveness of shear walls and the steel bracings in retrofitting the building was examined through nonlinear static and dynamic analyses. By using the nonlinear static analysis, retrofitted buildings seismic performances under lateral seismic load were compared with each other. Moreover, the performance points and response levels of the existing and retrofitting cases were determined by way of the capacity-spectrum method described in ATC-40 (1996). For the nonlinear dynamic analysis the records were selected torepresent wide ranges of duration and frequency content. Considering the change in the stiffness and the energy dissipation capacities, the performance of the existing and retrofitted buildings were evaluated in terms of story drifts and damage states. It was found that each earthquake record exhibited its own peculiarities, dictated by frequency content, duration, sequence of peaks and their amplitude. The seismic performance of retrofitted buildings resulted in lower displacements and higher energy dissipation capacity depending mainly on the properties of the ground motions and the retrofitting strategies. Moreover, severe structural damage (irreparable or collapse) was observed for the existing building. However, buildings with retrofit alternatives exhibited lower damage levels changing from no damage to irreparable damage states.  相似文献   

13.
In this study,dynamic responses of two buildings connected by viscoelastic dampers under bidirectional excitations are extensively investigated.The two buildings are a 10-story building and a 16-story building,with the shorter building on the left.Viscoelastic dampers are installed at all fl oors of the shorter building.Equations of motion are formulated using a fractional derivative model to represent the viscoelastic dampers.Three cases are considered with mass eccentricities at 0,10% and-10% with respect to the dimensions of the buildings.The responses of the buildings are numerically predicted at different damper properties.The simulation results indicated that the maximum horizontal responses of the buildings without eccentricities are signifi cantly mitigated.However,torsional effects are adversely increased.For asymmetric buildings,the effectiveness of the connecting dampers is affected by building eccentricities.As a result,mass eccentricities must be taken into account in damper selection.When compared with vibrations induced by unidirectional excitations,bidirectional excitations can increase the responses of coupled asymmetric buildings.In addition,installing dampers only at the top fl oor of the shorter building may cause a sudden change in lateral stiffness of the taller building.Consequently,the story shear envelopes of the taller building are changed.  相似文献   

14.
This paper presents a simplified method of evaluating the seismic performance of buildings. The proposed method is based on the transformation of a multiple degree of freedom (MDOF) system to an equivalent single degree of freedom (SDOF) system using a simple and intuitive process. The proposed method is intended for evaluating the seismic performance of the buildings at the intermediate stages in design, while a rigorous method would be applied to the final design. The performance of the method is evaluated using a series of buildings which are assumed to be located in Victoria in western Canada, and designed based on the upcoming version of the National Building Code of Canada which is due to be published in 2005. To resist lateral loads, some of these buildings contain reinforced concrete moment resisting frames,while others contain reinforced concrete shear walls. Each building model has been subjected to a set of site-specific seismic spectrum compatible ground motion records, and the response has been determined using the proposed method and the general method for MDOF systems. The results from the study indicate that the proposed method can serve as a useful tool for evaluation of seismic performance of buildings, and carrying out performance based design.  相似文献   

15.
This study investigates the seismic design factors for three reinforced concrete (RC) framed buildings with 4, 16 and 32-stories in Dubai, UAE utilizing nonlinear analysis. The buildings are designed according to the response spectrum procedure defined in the 2009 International Building Code (IBC’09). Two ensembles of ground motion records with 10% and 2% probability of exceedance in 50 years (10/50 and 2/50, respectively) are used. The nonlinear dynamic responses to the earthquake records are computed using IDARC-2D. Key seismic design parameters are evaluated; namely, response modification factor (R), deflection amplification factor (Cd), system overstrength factor (Ωo), and response modification factor for ductility (Rd) in addition to inelastic interstory drift. The evaluated seismic design factors are found to significantly depend on the considered ground motion (10/50 versus 2/50). Consequently, resolution to the controversy of Dubai seismicity is urged. The seismic design factors for the 2/50 records show an increase over their counterparts for the 10/50 records in the range of 200%-400%, except for the Ωo factor, which shows a mere 30% increase. Based on the observed trends, period-dependent R and Cd factors are recommended if consistent collapse probability (or collapse prevention performance) in moment frames with varying heights is to be expected.  相似文献   

16.
An accurate estimation of the applied load pattern is an essential component in each pushover procedure. Recently, a number of adaptive pushover methods have been proposed in which the effects of the higher modes as well as the progressive changes in the dynamic characteristics of structures are taken into account to compute the applied load pattern. The basic shortcoming of these advanced pushover methods is related to employing the quadratic modal combination rule, whereby the sign reversals of the modal load vectors are suppressed. In this study, an improved displacement-based adaptive pushover method is developed in which the applied load pattern is computed using the factor modal combination rule(FMC). In the proposed procedure, multiple load patterns, depending on the number of the modes considered, are determined in order to take into account the sign reversals of different modal load vectors. The accuracy of the proposed method is verifi ed for seven moment resisting frame buildings of 3, 9 and 20 stories with regularity or vertically geometric and mass irregularities subjected to 60 earthquake ground motion records. The results showed that the proposed methodology is capable of reproducing the peak dynamic responses with very good accuracy.  相似文献   

17.
This paper outlines a methodology to assess the seismic drift of reinforced concrete buildings with limited structural and geotechnical information. Based on the latest and the most advanced research on predicting potential near-field and far field earthquakes affecting Hong Kong, the engineering response spectra for both rock and soil sites are derived. A new step-by-step procedure for displacement-based seismic hazard assessment of building structures is proposed to determine the maximum inter-storey drift demand for reinforced concrete buildings. The primary information required for this assessment is only the depth of the soft soil above bedrock and the height of the building. This procedure is further extended to assess the maximum chord rotation angle demand for the coupling beam of coupled shear wall or frame wall structures, which may be very critical when subjected to earthquake forces. An example is provided to illustrate calibration of the assessment procedure by using actual engineering structural models.  相似文献   

18.
The nonlinear behavior of a soil-foundation system may alter the seismic response of a structure by providing additional flexibility to the system and dissipating hysteretic energy at the soil-foundation interface. However, the current design practice is still reluctant to consider the nonlinearity of the soil-foundation system, primarily due to lack of reliable modeling techniques. This study is motivated towards evaluating the effect of nonlinear soil-structure interaction (SSI) on the seismic responses of low-rise steel moment resisting frame (SMRF) structures. In order to achieve this, a Winkler-based approach is adopted, where the soil beneath the foundation is assumed to be a system of closely-spaced, independent, nonlinear spring elements. Static pushover analysis and nonlinear dynamic analyses are performed on a 3-story SMRF building and the performance of the structure is evaluated through a variety of force and displacement demand parameters. It is observed that incorporation of nonlinear SSI leads to an increase in story displacement demand and a significant reduction in base moment, base shear and inter-story drift demands, indicating the importance of its consideration towards achieving an economic, yet safe seismic design.  相似文献   

19.
It is known that structural stiffness and strength distributions have an important role in the seismic response of buildings.The effect of using different code-specified lateral load patterns on the seismic performance of fixed-base buildings has been investigated by researchers during the past two decades.However,no investigation has yet been carried out for the case of soil-structure systems.In the present study,through intensive parametric analyses of 21,600 linear and nonlinear MDOF systems and considering five different shear strength and stiffness distribution patterns,including three code-specified patterns as well as uniform and concentric patterns subjected to a group of earthquakes recorded on alluvium and soft soils,the effect of structural characteristics distribution on the strength demand and ductility reduction factor of MDOF fixed-base and soil-structure systems are parametrically investigated.The results of this study show that depending on the level of inelasticity,soil flexibility and number of degrees-of-freedoms(DOFs),structural characteristics distribution can significantly affect the strength demand and ductility reduction factor of MDOF systems.It is also found that at high levels of inelasticity,the ductility reduction factor of low-rise MDOF soil-structure systems could be significantly less than that of fixed-base structures and the reduction is less pronounced as the number of stories increases.  相似文献   

20.
Major damage has been reported in hilly areas after major earthquakes,primarily because of two special conditions:the variation in the seismic ground motion due to the inclined ground surface and the irregularities caused by a stepped base level in the structure.The aim of this study is to evaluate possible differences in the responses of Chilean hillside buildings through numerical linear-elastic and nonlinear analyses.In the first step,a set of response-spectrum analyses were performed on four simplified 2D structures with mean base inclination angles of 0°,15°,30°,and 45°.The structures were designed to comply with Chilean seismic codes and standards,and the primary response parameters were compared.To assess the seismic performance of the buildings,nonlinear static(pushover)and dynamic(time-history)analyses were performed with SeismoStruct software.Pushover analyses were used to compare the nonlinear response at the maximum roof displacement and the damage patterns.Time-history analyses were performed to assess the nonlinear dynamic response of the structures subjected to seismic ground motions modified by topographic effects.To consider the topographic modification,acceleration records were obtained from numerical models of soil,which were calculated using the rock acceleration record of the Mw 8.01985 Chilean earthquake.Minor differences in the structure responses(roof displacements and maximum element forces and moments)were caused by the topographic effects in the seismic input motion,with the highly predominant ones being the differences caused by the step-back configuration at the base of the structures.High concentrations of shear forces in short walls were observed,corresponding to the walls located in the upper zone of the foundation system.The response of the structures with higher angles was observed to be more prone to fragile failures due to the accumulation of shear forces.Even though hillside buildings gain stiffness in the lower stories,resulting in lower design roof displacement,maximum roof displacements for nonlinear time-history analyses remained very close for all the models that were primarily affected by the drifts of the lower stories.Additionally,vertical parasitic accelerations were considered for half the time-history analyses performed here.The vertical component seems to considerably modify the axial load levels in the shear walls on all stories.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号